WaterCompared

Water report · not indexed

What is in the water at 06042

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

CTWC - NORTHERN REG-WESTERN SYSTEM

PWSID CT0473011 · CT · serves 101,313 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 20 samples.

CompoundHighest detectedSamplesMost recent
lithium20 µg/L27/1/2025
PFOA0.008 µg/L89/4/2024
PFOS0.006 µg/L47/26/2024
PFBA0.005 µg/L17/1/2025
PFHxS0.003 µg/L17/1/2025
PFBS0.003 µg/L17/1/2025
PFPeA0.003 µg/L27/23/2024
PFHxA0.003 µg/L17/1/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 46 mg/L as CaCO₃, measured at 8 stations serving this system across 323 results, 2015-01-14 to 2023-11-06. Measured in the water source and distribution area, not at a tap, and not in your home.

MANCHESTER WATER DEPARTMENT

PWSID CT0770021 · CT · serves 51,198 people

PFAS and lithium

7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 44 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.016 µg/L67/22/2024
PFBS0.015 µg/L54/24/2024
PFOA0.013 µg/L147/23/2024
PFPeA0.0047 µg/L54/24/2024
PFHxA0.0047 µg/L87/22/2024
PFHxS0.0038 µg/L44/24/2024
PFHpA0.0035 µg/L24/23/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 4 station(s), 4 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.