WaterCompared

Water report · not indexed

What is in the water at 08750

4 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

WALL TWP WATER DEPT

PWSID NJ1352003 · NJ · serves 26,000 people

PFAS and lithium

4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 20 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.0066 µg/L69/19/2023
PFOS0.005 µg/L49/19/2023
PFHxA0.0039 µg/L69/19/2023
PFPeA0.0038 µg/L49/19/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 55 mg/L as CaCO₃, measured at 2 stations serving this system across 14 results, 2015-07-06 to 2022-09-20. Measured in the water source and distribution area, not at a tap, and not in your home.

BOROUGH OF SPRINGLAKE HEIGHTS

PWSID NJ1349001 · NJ · serves 5,000 people

PFAS and lithium

5 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 10 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.0068 µg/L47/17/2023
PFOS0.0048 µg/L110/9/2023
PFPeA0.0041 µg/L27/17/2023
PFHxA0.004 µg/L27/17/2023
PFHxS0.003 µg/L110/9/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

MANASQUAN WATER DEPARTME

PWSID NJ1327001 · NJ · serves 14,000 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

SEA GIRT WATER DEPT

PWSID NJ1344001 · NJ · serves 2,636 people

PFAS and lithium

Not sampled for PFAS. EPA’s UCMR 5 monitoring covered every system serving more than 3,300 people and only a sample of smaller ones. This system was not in it, so there is no result to show, which is not the same as a result showing nothing.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.