WaterCompared

Water report · not indexed

What is in the water at 10901

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

VEOLIA WATER NEW YORK

PWSID NY4303673 · NY · serves 270,000 people

PFAS and lithium

11 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 115 samples.

CompoundHighest detectedSamplesMost recent
lithium19 µg/L215/9/2023
PFOA0.014 µg/L357/11/2023
6:2 FTS0.012 µg/L35/23/2023
PFPeA0.01 µg/L177/11/2023
PFHxA0.0076 µg/L167/11/2023
PFBA0.0068 µg/L45/8/2023
PFOS0.0068 µg/L55/9/2023
PFHxS0.0062 µg/L15/8/2023
PFHpA0.0056 µg/L47/11/2023
PFNA0.0054 µg/L25/23/2023
PFBS0.005 µg/L75/9/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

10 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 1028 · began 2022-01-01
  • MCL · contaminant code 2950 · began 2016-01-01
  • MCL · contaminant code 2806 · began 2024-07-01
  • MCL · contaminant code 2806 · began 2024-07-01
  • MCL · contaminant code 2806 · began 2025-04-01
  • MCL · contaminant code 2806 · began 2025-07-01
  • MCL · contaminant code 2806 · began 2025-07-01
  • MCL · contaminant code 2805 · began 2025-07-01

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

SUFFERN VILLAGE

PWSID NY4303675 · NY · serves 12,000 people

PFAS and lithium

4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 8 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.0074 µg/L27/23/2024
PFPeA0.0068 µg/L27/23/2024
PFOS0.0059 µg/L27/23/2024
PFHxA0.005 µg/L27/23/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.