WaterCompared

Water report · not indexed

What is in the water at 18960

3 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

PERKASIE REGIONAL AUTHORITY

PWSID PA1090046 · PA · serves 15,000 people

PFAS and lithium

5 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 20 samples.

CompoundHighest detectedSamplesMost recent
lithium20 µg/L87/16/2024
PFOS0.018 µg/L67/16/2024
PFOA0.0065 µg/L37/16/2024
PFHxS0.0051 µg/L17/16/2024
PFBS0.0049 µg/L27/16/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

HILLTOWN TWP WATER&SEWER AUTH

PWSID PA1090117 · PA · serves 5,770 people

PFAS and lithium

6 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 16 samples.

CompoundHighest detectedSamplesMost recent
lithium23 µg/L69/24/2025
PFOA0.008 µg/L29/23/2025
PFOS0.0068 µg/L29/23/2025
PFPeA0.0066 µg/L29/23/2025
PFBS0.0057 µg/L29/23/2025
PFHxA0.0055 µg/L29/23/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

NORTH PENN WATER AUTHORITY

PWSID PA1460034 · PA · serves 91,941 people

PFAS and lithium

4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 21 samples.

CompoundHighest detectedSamplesMost recent
lithium24 µg/L84/10/2024
PFOA0.0051 µg/L54/10/2024
PFBS0.004 µg/L64/10/2024
PFPeA0.0034 µg/L24/10/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 161 mg/L as CaCO₃, measured at 5 stations serving this system across 19 results, 2015-02-04 to 2020-09-21. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.