WaterCompared

Water report · not indexed

What is in the water at 27258

4 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

BURLINGTON, CITY OF

PWSID NC0201010 · NC · serves 60,985 people

PFAS and lithium

7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 22 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.017 µg/L87/12/2024
PFOA0.013 µg/L77/12/2024
6:2 FTS0.0097 µg/L112/18/2024
PFHxA0.0044 µg/L37/12/2024
PFHpA0.0042 µg/L17/12/2024
PFPeA0.0041 µg/L17/12/2024
PFHxS0.0032 µg/L17/12/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

GRAHAM, CITY OF

PWSID NC0201015 · NC · serves 18,354 people

PFAS and lithium

5 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 14 samples.

CompoundHighest detectedSamplesMost recent
PFBS0.011 µg/L48/12/2024
PFOA0.0076 µg/L48/12/2024
PFOS0.0074 µg/L48/12/2024
PFHxA0.0035 µg/L111/13/2023
PFPeA0.0034 µg/L111/13/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 16 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

ORANGE-ALAMANCE WATER SYSTEM

PWSID NC0368020 · NC · serves 9,223 people

PFAS and lithium

5 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 16 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.012 µg/L44/9/2025
PFOA0.0094 µg/L44/9/2025
PFHxA0.0041 µg/L34/9/2025
PFPeA0.0039 µg/L210/15/2025
PFHpA0.0033 µg/L34/9/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

3 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • TT · contaminant code 2920 · began 2025-07-01
  • TT · contaminant code 2920 · began 2025-10-01
  • TT · contaminant code 2920 · began 2026-01-01

Hardness

Too few readings to state a hardness. 1 station(s), 13 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

COPPER TRACE S/D

PWSID NC3001006 · NC

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.