WaterCompared

Water report · not indexed

What is in the water at 27540

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

HARNETT REGIONAL WATER

PWSID NC0343045 · NC · serves 116,892 people

PFAS and lithium

7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 22 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.012 µg/L49/9/2025
PFOA0.0077 µg/L49/9/2025
PFHxA0.0071 µg/L49/9/2025
PFPeA0.0069 µg/L49/9/2025
PFHpA0.0036 µg/L29/9/2025
PFBS0.0034 µg/L29/9/2025
PFHxS0.0031 µg/L29/9/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 24 mg/L as CaCO₃, measured at 2 stations serving this system across 21 results, 2015-09-01 to 2025-11-06. Measured in the water source and distribution area, not at a tap, and not in your home.

HOLLY SPRINGS, TOWN OF

PWSID NC0392050 · NC · serves 45,058 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 25 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.012 µg/L48/6/2024
PFPeA0.0081 µg/L48/6/2024
PFHxA0.0074 µg/L48/6/2024
PFBA0.007 µg/L25/7/2024
PFOA0.0059 µg/L48/6/2024
PFBS0.0045 µg/L38/6/2024
PFHpA0.0034 µg/L28/6/2024
PFHxS0.0032 µg/L28/6/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.