Water report · not indexed
What is in the water at 28312
4 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.
BLADEN CO WTR DIST-EAST BLADEN
PWSID NC0309060 · NC · serves 3,889 people
PFAS and lithium
2 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 3 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| lithium | 9.3 µg/L | 2 | 3/15/2023 |
| HFPO-DA | 0.014 µg/L | 1 | 3/15/2023 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.
Hardness
No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.
FAYETTEVILLE PUBLIC WORKS COMM
PWSID NC0326010 · NC · serves 215,590 people
PFAS and lithium
9 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 58 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| PFOS | 0.022 µg/L | 8 | 7/10/2024 |
| PFPeA | 0.022 µg/L | 8 | 7/10/2024 |
| PFHxS | 0.019 µg/L | 8 | 7/10/2024 |
| PFHxA | 0.018 µg/L | 8 | 7/10/2024 |
| PFBS | 0.012 µg/L | 8 | 7/10/2024 |
| PFBA | 0.011 µg/L | 4 | 7/10/2024 |
| PFOA | 0.011 µg/L | 8 | 7/10/2024 |
| 6:2 FTS | 0.0077 µg/L | 1 | 10/17/2023 |
| PFHpA | 0.007 µg/L | 5 | 7/10/2024 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.
Hardness
Median hardness 23 mg/L as CaCO₃, measured at 4 stations serving this system across 38 results, 2015-09-01 to 2025-11-13. Measured in the water source and distribution area, not at a tap, and not in your home.
DUNN, CITY OF
PWSID NC0343010 · NC · serves 12,442 people
PFAS and lithium
8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 32 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| PFPeA | 0.022 µg/L | 4 | 7/28/2023 |
| PFHxA | 0.02 µg/L | 4 | 7/28/2023 |
| PFOS | 0.014 µg/L | 4 | 7/28/2023 |
| PFBS | 0.014 µg/L | 4 | 7/28/2023 |
| PFBA | 0.013 µg/L | 4 | 7/28/2023 |
| PFOA | 0.012 µg/L | 4 | 7/28/2023 |
| PFHpA | 0.0076 µg/L | 4 | 7/28/2023 |
| PFHxS | 0.0052 µg/L | 4 | 7/28/2023 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.
Hardness
No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.
EASTOVER SANITARY DISTRICT
PWSID NC5026027 · NC
PFAS and lithium
8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 27 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| PFOS | 0.014 µg/L | 4 | 8/12/2025 |
| PFOA | 0.01 µg/L | 4 | 8/12/2025 |
| PFPeA | 0.0095 µg/L | 4 | 8/12/2025 |
| PFHxA | 0.0087 µg/L | 4 | 8/12/2025 |
| PFBA | 0.0063 µg/L | 3 | 5/12/2025 |
| PFHpA | 0.0048 µg/L | 3 | 5/12/2025 |
| PFBS | 0.0044 µg/L | 3 | 5/12/2025 |
| PFHxS | 0.0041 µg/L | 2 | 2/12/2025 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.
Hardness
No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.
What this report cannot tell you
Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.
Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.