WaterCompared

Water report · not indexed

What is in the water at 28401

3 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

BRUNSWICK COUNTY WATER SYSTEM

PWSID NC0410045 · NC · serves 142,227 people

PFAS and lithium

9 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 26 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.012 µg/L48/3/2023
PFPeA0.012 µg/L38/3/2023
PFHxA0.0098 µg/L38/3/2023
PFBA0.0085 µg/L38/3/2023
PFOA0.0077 µg/L38/3/2023
PFBS0.0071 µg/L38/3/2023
HFPO-DA0.0058 µg/L110/16/2023
PFHxS0.0052 µg/L38/3/2023
PFHpA0.0041 µg/L38/3/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 10 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

CFPUA-WILMINGTON

PWSID NC0465010 · NC · serves 181,242 people

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 1 sample.

CompoundHighest detectedSamplesMost recent
PFPeA0.0044 µg/L112/5/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 214 mg/L as CaCO₃, measured at 30 stations serving this system across 31 results, 2017-05-08 to 2022-08-22. Measured in the water source and distribution area, not at a tap, and not in your home.

PENDER COUNTY UTILITIES

PWSID NC7071011 · NC · serves 31,600 people

PFAS and lithium

4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 8 samples.

CompoundHighest detectedSamplesMost recent
PFPeA0.0076 µg/L38/15/2023
PFBS0.0053 µg/L18/15/2023
PFBA0.005 µg/L18/15/2023
PFHxA0.0048 µg/L38/15/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

4 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 2950 · began 2025-04-01
  • MCL · contaminant code 2950 · began 2025-07-01
  • MCL · contaminant code 2950 · began 2025-10-01
  • MCL · contaminant code 2950 · began 2026-01-01

Hardness

Too few readings to state a hardness. 1 station(s), 39 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.