WaterCompared

Water report · not indexed

What is in the water at 33030

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

HOMESTEAD, CITY OF

PWSID FL4130645 · FL · serves 80,000 people

PFAS and lithium

2 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 8 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.026 µg/L49/23/2025
PFBS0.0097 µg/L49/23/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 238 mg/L as CaCO₃, measured at 5 stations serving this system across 6 results, 2016-03-09 to 2017-05-17. Measured in the water source and distribution area, not at a tap, and not in your home.

MDWASA/REX UTILITIES

PWSID FL4131202 · FL

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 58 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.037 µg/L108/12/2025
PFBS0.017 µg/L108/12/2025
PFPeA0.015 µg/L68/12/2025
PFHxA0.011 µg/L68/12/2025
PFOA0.011 µg/L68/12/2025
PFBA0.0098 µg/L98/12/2025
PFHpA0.0066 µg/L68/12/2025
PFHxS0.0038 µg/L58/12/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.