WaterCompared

Water report · not indexed

What is in the water at 71245

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

GRAMBLING STATE UNIVERSITY WS

PWSID LA1061005 · LA

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

1 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • TT · contaminant code 0700 · began 2025-01-01

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

GRAMBLING WATER SYSTEM

PWSID LA1061006 · LA · serves 4,949 people · service area inferred by a model, not supplied by the state

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 1 sample.

CompoundHighest detectedSamplesMost recent
lithium9.4 µg/L14/23/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

9 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • TT · contaminant code 0700 · began 2023-05-08
  • TT · contaminant code 0700 · began 2023-05-08
  • TT · contaminant code 0700 · began 2025-10-13
  • TT · contaminant code 0700 · began 2025-10-13
  • TT · contaminant code 0700 · began 2025-10-13
  • TT · contaminant code 0700 · began 2025-10-13
  • TT · contaminant code 0700 · began 2025-10-13
  • TT · contaminant code 0700 · began 2025-10-13

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01 · 1 of 2 service areas here are modelled.