WaterCompared

Water report · not indexed

What is in the water at 75024

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

CITY OF PLANO

PWSID TX0430007 · TX · serves 288,800 people

PFAS and lithium

4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 11 samples.

CompoundHighest detectedSamplesMost recent
PFBA0.0073 µg/L28/13/2025
PFHxA0.0044 µg/L48/13/2025
PFPeA0.0043 µg/L48/13/2025
PFBS0.0031 µg/L111/5/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

CITY OF THE COLONY

PWSID TX0610081 · TX · serves 45,367 people

PFAS and lithium

5 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 36 samples.

CompoundHighest detectedSamplesMost recent
lithium77 µg/L66/26/2023
PFBA0.0087 µg/L88/15/2023
PFPeA0.0076 µg/L88/15/2023
PFHxA0.0075 µg/L78/15/2023
PFBS0.0041 µg/L78/15/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 119 mg/L as CaCO₃, measured at 2 stations serving this system across 240 results, 2018-01-24 to 2023-08-01. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.