Water report · not indexed
What is in the water at 76549
4 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.
CITY OF KILLEEN
PWSID TX0140006 · TX · serves 151,261 people
PFAS and lithium
4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 11 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| lithium | 21 µg/L | 3 | 9/2/2025 |
| PFBA | 0.0073 µg/L | 4 | 9/2/2025 |
| PFPeA | 0.0035 µg/L | 3 | 9/2/2025 |
| PFBS | 0.003 µg/L | 1 | 6/2/2025 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.
Hardness
Too few readings to state a hardness. 1 station(s), 2 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.
WEST BELL COUNTY WSC
PWSID TX0140105 · TX · serves 4,710 people
PFAS and lithium
8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 11 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| lithium | 23 µg/L | 3 | 6/5/2023 |
| PFPeA | 0.01 µg/L | 1 | 6/5/2023 |
| PFBS | 0.0088 µg/L | 1 | 6/5/2023 |
| PFHxS | 0.0074 µg/L | 1 | 6/5/2023 |
| PFHxA | 0.0069 µg/L | 1 | 6/5/2023 |
| PFBA | 0.0067 µg/L | 2 | 6/5/2023 |
| PFOS | 0.0059 µg/L | 1 | 6/5/2023 |
| PFHpA | 0.0031 µg/L | 1 | 6/5/2023 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.
Hardness
No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.
KEMPNER WSC
PWSID TX1410028 · TX · serves 17,721 people
PFAS and lithium
4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 8 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| lithium | 14 µg/L | 2 | 2/27/2025 |
| PFBA | 0.0094 µg/L | 1 | 8/28/2024 |
| PFBS | 0.0036 µg/L | 2 | 2/27/2025 |
| PFPeA | 0.0035 µg/L | 3 | 8/28/2024 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.
Hardness
No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.
CITY OF GEORGETOWN
PWSID TX2460001 · TX · serves 133,743 people
PFAS and lithium
8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 87 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| lithium | 17 µg/L | 10 | 9/20/2023 |
| PFBA | 0.034 µg/L | 13 | 9/23/2024 |
| PFPeA | 0.019 µg/L | 19 | 9/23/2024 |
| PFHxA | 0.01 µg/L | 11 | 9/20/2023 |
| PFBS | 0.0096 µg/L | 19 | 9/23/2024 |
| PFOS | 0.0057 µg/L | 3 | 9/20/2023 |
| PFOA | 0.0049 µg/L | 1 | 9/20/2023 |
| PFHxS | 0.0047 µg/L | 11 | 9/20/2023 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
1 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.
- MCL · contaminant code 2950 · began 2026-04-01
Hardness
Median hardness 239 mg/L as CaCO₃, measured at 3 stations serving this system across 7 results, 2015-09-28 to 2022-10-18. Measured in the water source and distribution area, not at a tap, and not in your home.
What this report cannot tell you
Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.
Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.