WaterCompared

Water report · not indexed

What is in the water at 77979

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

CITY OF PORT LAVACA

PWSID TX0290002 · TX · serves 11,545 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 23 samples.

CompoundHighest detectedSamplesMost recent
lithium15 µg/L37/25/2023
PFPeA0.016 µg/L48/14/2024
PFBA0.014 µg/L48/14/2024
PFHxA0.01 µg/L48/14/2024
PFHxS0.0072 µg/L38/14/2024
PFBS0.0065 µg/L28/14/2024
PFOA0.006 µg/L24/18/2023
PFOS0.0047 µg/L14/18/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

14 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 2950 · began 2023-01-01
  • MCL · contaminant code 2950 · began 2023-04-01
  • MCL · contaminant code 2950 · began 2023-07-01
  • MCL · contaminant code 2950 · began 2023-10-01
  • MCL · contaminant code 2950 · began 2024-01-01
  • MCL · contaminant code 2950 · began 2024-04-01
  • MCL · contaminant code 2950 · began 2024-07-01
  • MCL · contaminant code 2950 · began 2024-10-01

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

GBRA CALHOUN COUNTY RURAL WATER SYSTEM

PWSID TX0290007 · TX · serves 4,482 people

PFAS and lithium

9 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 48 samples.

CompoundHighest detectedSamplesMost recent
lithium19 µg/L88/20/2024
6:2 FTS0.051 µg/L111/4/2024
PFPeA0.014 µg/L88/20/2024
PFBA0.0077 µg/L45/6/2024
PFHxA0.0072 µg/L88/20/2024
PFBS0.0054 µg/L88/20/2024
PFOS0.005 µg/L18/20/2024
PFOA0.0048 µg/L28/20/2024
PFHxS0.0047 µg/L88/20/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

11 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 2950 · began 2023-10-01
  • MCL · contaminant code 2950 · began 2024-01-01
  • MCL · contaminant code 2950 · began 2024-04-01
  • MCL · contaminant code 2950 · began 2024-07-01
  • MCL · contaminant code 2950 · began 2024-10-01
  • MCL · contaminant code 2950 · began 2025-01-01
  • MCL · contaminant code 2950 · began 2025-04-01
  • MCL · contaminant code 2950 · began 2025-07-01

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.