5 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

AZUSA LIGHT AND WATER

PWSID CA1910007 · CA · serves 110,044 people

PFAS and lithium

3 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 6 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.0077 µg/L26/12/2024
PFOS0.0058 µg/L36/12/2024
PFHxA0.0035 µg/L112/14/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 2 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

VALLEY COUNTY WATER DIST.

PWSID CA1910009 · CA · serves 68,871 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

SAN GABRIEL VALLEY WATER CO.-EL MONTE

PWSID CA1910039 · CA · serves 248,000 people

PFAS and lithium

2 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 2 samples.

CompoundHighest detectedSamplesMost recent
PFBA0.01 µg/L12/28/2025
PFPeA0.0056 µg/L12/28/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 255 mg/L as CaCO₃, measured at 8 stations serving this system across 10 results, 2015-08-13 to 2022-04-14. Measured in the water source and distribution area, not at a tap, and not in your home.

VALLEY VIEW MUTUAL WATER CO.

PWSID CA1910165 · CA · serves 4,613 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

CAL-AM WATER COMPANY - DUARTE

PWSID CA1910186 · CA · serves 24,773 people

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 1 sample.

CompoundHighest detectedSamplesMost recent
PFOS0.0051 µg/L110/12/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.