WaterCompared

Water report · not indexed

What is in the water at 93043

4 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

UNITED WTR CONS DIST

PWSID CA5610046 · CA

PFAS and lithium

Not sampled for PFAS. EPA’s UCMR 5 monitoring covered every system serving more than 3,300 people and only a sample of smaller ones. This system was not in it, so there is no result to show, which is not the same as a result showing nothing.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 525 mg/L as CaCO₃, measured at 19 stations serving this system across 21 results, 2017-06-26 to 2022-03-16. Measured in the water source and distribution area, not at a tap, and not in your home.

OXNARD WATER DEPT

PWSID CA5610007 · CA · serves 200,232 people

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 12 samples.

CompoundHighest detectedSamplesMost recent
lithium39 µg/L129/20/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 4 station(s), 4 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

PORT HUENEME WATER AGENCY

PWSID CA5610080 · CA

PFAS and lithium

Not sampled for PFAS. EPA’s UCMR 5 monitoring covered every system serving more than 3,300 people and only a sample of smaller ones. This system was not in it, so there is no result to show, which is not the same as a result showing nothing.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

NAVAL BASE VENTURA COUNTY, PORT HUENEME

PWSID CA5610701 · CA · serves 8,625 people

PFAS and lithium

Not sampled for PFAS. EPA’s UCMR 5 monitoring covered every system serving more than 3,300 people and only a sample of smaller ones. This system was not in it, so there is no result to show, which is not the same as a result showing nothing.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.